1-800-DAWN-SCI  |   732-902-6300  |   sales@dawnscientific.com
Attention: If you are experiencing any checkout issues, please call 732-902-6300 | We are currently updating the price listed on our website.
  • Get quote
  • Find SDS & COA
  • Join Us
  • Support
    • Literature
    • Distributor Download
    • FAQs
  • Contact
DAWN SCIENTIFIC DAWN SCIENTIFIC
ISO 9001:2015 Certified
Login / Register

Sign inCreate an Account

Lost your password?
0 items / $0.00
Menu
DAWN SCIENTIFIC
0 items / $0.00
  • About
  • Chemicals
    • Acids & Base
    • Alcohols
    • Amino Acids & Resin
    • Buffer & Volumetric Solutions
    • High Purity Solvents
    • Inorganic Reagents
    • Organic Reagents
    • Peroxides
    • Reference Standard
    • Water
  • Consumables & Supply
    • Chromatography
    • Consumables
    • Filtration
    • Glassware
    • Hydrometers
    • Plasticware
    • pH measure
    • Sanitizing Products
    • Stopwatches
    • Thermometers
    • Timers
    • Weighing Dishes
  • Equipments
    • Incubators
    • Laboratory Instruments
    • Laboratory Equipment
    • Laboratory Weighing
    • Refractometers & Polarimeters
  • ChemieR
    • Acids
    • High Purity Solvents
    • Inorganic Reagent
  • cUSP Solutions
    • Buffer Solutions
    • Percentage Solutions
    • Test Solutions
    • Test Solutions Kit
    • Volumetric Solutions
  • Tristain
    • Indicator
      • Solid
      • Solutions
    • Stains
      • Solid
      • Solutions
    • Stain Kit
  • Kappaa
    • Amino Acids & Resin
  • LiChrom
    • HPLC Buffer Salt
    • HPLC Ion-Pair Reagent
    • HPLC Solvents
  • Bluster
    • Bluster GC
    • Bluster GC-HS
  • EKS
  • Bulk Packaging
  • Suppliers
Click to enlarge
Contact Form Demo (#3)
HomeEquipmentsLaboratory Equipment Analytical Models, Series Tx and Dx internal calibration
accuris

W3102A-

Analytical Models, Series Tx and Dx internal calibration

$2,012.00 – $3,556.00

Available Options:

Share
Facebook Twitter Email Pinterest linkedin WhatsApp
  • Description
  • Reviews (0)
  • Attachment
  • About Accuris
  • Specifications
Description

The Series Tx analytical balances are the most advanced in the Accuris line. The large, high resolution touch screen presents the user with an icon-based menu system and allows quick and intuitive access to a wide range of useful functions. A precisely engineered Electromagnetic Force Restoration (EFR) weigh cell accurately determines masses to sub milligram levels.

Two models are available in the Tx Series: The W3102A-220 has a max capacity of 220g and readability of 0.1 mg. The W3002A-120 is a semi-micro class balance with a maximum capacity of 120g, and readability of 0.01mg up to 62g.

The Tx internal calibration system helps ensure that the balance is always calibrated and ready for use. Auto calibration can also be set to occur at specific time intervals depending on user preference. A high resolution thermal probe is incorporated in the core of the EFR weigh cell, and if measured temperature fluctuates slightly, the balance will automatically compensate.

A USB port on the side accepts a flash drives for storage of weighing data, which can then be transferred to a computer.

Series Tx models have adjustable feet and a leveling bubble to ensure correct installation. Note: For optimal weighing performance, the Tx semi micro model must be installed on a suitably stable surface such as a marble slab table.

The new AccuCheck System from Accuris Instruments gives your lab the freedom to calibrate pipettes quickly and when required. The system combines our popular Tx touch screen analytical balance with an anti evaporation trap accessory and built-in pipette calibration software. Together, this standalone pipette calibration system is easy for any lab tech to use for the ISO 8655 method of pipette calibration.

The user interface of the AccuCheckâ„¢ software is intuitive and requires no special training to use. Individual pipette details (brand, model, serial number) can be saved in the internal data base for current and future calibrations. The software walks the user through all steps of the gravimetric method, allows input of water temp, air temp, pressure, and humidity. It saves the weight values, and then performs all calculations for accuracy and precision at 3 volume settings. The Anti Evaporation Trap greatly improves results when performing the gravimetric method by preventing unstable measurements due to evaporation loss.

Removing the Anti Evaporation Trap allows the Tx Semi-Micro balance to be used for general weighing applications. Offering a maximum capacity of 120g, readability of 62gx0.01mg / 120gx0.1mg, and automatic internal calibration, the Tx balance is a favorite for labs needing fast and accurate weight determinations.

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Analytical Models, Series Tx and Dx internal calibration” Cancel reply

Your email address will not be published. Required fields are marked *

Attachment

About Accuris

Accuris product development team has over 25 combined years of experience in the precision liquid handling business. We were assigned the challenge to create a next generation pipette, to be the lightest and most ergonomic that we have ever introduced, without compromising performance or durability.

Specifications
Model W3002A-120 W3102A-220
Capacity 120 grams 220 grams
Readability 62g x 0.00001 grams / 120g x 0.0001 grams 0.0001 grams
Linearity ± 0.08mg / ± 0.2mg ± 0.2mg
Repeatability ± 0.03mg / ± 0.1mg ± 0.1mg
 Pan size (Round)  80 mm 80 mm
Draft Shield  yes, glass yes, glass
Weighing Units  g, mg, carats, oz, lbs, dwt, t oz, gn, % g, mg, carats, oz, lbs, dwt, t oz, gn, %
Calibration  Internal Quick Cal and External  Internal Quick Cal and External
Display 5.25 x 1.5 inch, color touch screen 5.25 x 1.5 inch, color touch screen
Exterior Dims.  13.5  x 8.5 x 13 inches 13.5  x 8.5 x 13 inches
Connectivity  USB and RS232 USB and RS232
Product Weight 13 Lbs. /  6 Kg 13 Lbs. / 6 Kg
Dawn Scientific is woman owned small business located in central New Jersey. We have been serving our esteemed customers from various industries since 1978.
Contact us
  • 121 Liberty Street, Metuchen, NJ, 08840
  • 732-902-6300
  • 973-802-1005
  • sales@dawnscientific.com
Useful Links
  • Blogs
  • Useful Links
  • Catalogue
  • Privacy Policy
  • Cancellation Policy

PayPal Acceptance Mark

ACCREDITATION

ISO 9001:2015
WBENC
SBA

MEMBERSHIPS

ILDA

My Account
  • Login / Sign-Up
  • Order History
  • My Lists
DAWN SCIENTIFIC INC 2019 CREATED BY DIVINE INFOSERVICES PVT.LTD

Shopping cart

close
  • About
  • Chemicals
    • Acids & Base
    • Alcohols
    • Amino Acids & Resin
    • Buffer & Volumetric Solutions
    • High Purity Solvents
    • Inorganic Reagents
    • Organic Reagents
    • Peroxides
    • Reference Standard
    • Water
  • Consumables & Supply
    • Chromatography
    • Consumables
    • Filtration
    • Glassware
    • Hydrometers
    • Plasticware
    • pH measure
    • Sanitizing Products
    • Stopwatches
    • Thermometers
    • Timers
    • Weighing Dishes
  • Equipments
    • Incubators
    • Laboratory Instruments
    • Laboratory Equipment
    • Laboratory Weighing
    • Refractometers & Polarimeters
  • ChemieR
    • Acids
    • High Purity Solvents
    • Inorganic Reagent
  • cUSP Solutions
    • Buffer Solutions
    • Percentage Solutions
    • Test Solutions
    • Test Solutions Kit
    • Volumetric Solutions
  • Tristain
    • Indicator
      • Solid
      • Solutions
    • Stains
      • Solid
      • Solutions
    • Stain Kit
  • Kappaa
    • Amino Acids & Resin
  • LiChrom
    • HPLC Buffer Salt
    • HPLC Ion-Pair Reagent
    • HPLC Solvents
  • Bluster
    • Bluster GC
    • Bluster GC-HS
  • EKS
  • Bulk Packaging
  • Suppliers
  • Wishlist
  • Login / Register
Scroll To Top
Facebook Twitter Instagram YouTube Pinterest linkedin